> TROUBLESHOOTING > When the date, indicator hand or hour/minute/seconds hand position is misaligned

When the date, indicator hand or hour/minute/seconds hand position is misaligned

Points to be checked

Reception was successful (the reception result is displayed as “Y”), but time has gained or lost.

The set time difference (including DST (daylight saving time or “summer time”)) may differ.

When the time difference setting differs from the current location, set the time difference through one of these operations.
When in a location with good reception How to adjust the time zone
When in a location with no reception How to perform manual time difference setting (selection)

Automatic time adjustment may not get activated for a few days.
Automatic time adjustment

The automatic time adjustment function is unlikely to be activated due to low energy stored in the watch or depending on the environment.
To immediately adjust the time, refer to How to adjust the time zone.

Preliminary position

When the watch is unable to display the precise time or date, or the indicator hand does not point to the correct position even when it has successfully received GPS signals, the preliminary position may be misaligned.

The preliminary position is misaligned due to the following reasons.

Reference position_impact_00

Strong impact such as dropping or hitting

Reference position_magnetic_00

Things around you which generate magnetism
Examples of common magnetic products that may affect watches

When comparing the state of “Misaligned Preliminary Hand Position” to that of a weight scale, it is like “a scale which is unable to display the correct weight because its needle is not set to the zero position before weighing.”

Setting the preliminary position of the hour, minute, and seconds hands (automatic hand position alignment function)

The “automatic hand position alignment function” automatically adjusts the hour, minute, and seconds hands when the preliminary positions are incorrect.

The automatic hand position alignment function acts once per 12 hours for the hour hand (at noon and midnight), once per hour for the minute hand, and once per minute for the seconds hand.

This function works when the preliminary hand position is misaligned due to external factors such as strong impact or magnetic influence.
It does not work to adjust accuracy of the watch or slight misalignment which may occur during the manufacturing process.

The preliminary positions of the hour and minute hands can be adjusted manually.
Adjusting the preliminary position of the date, indicator hand, and hour/minute hands

Setting the preliminary position of the date and indicator hand

As the preliminary position of the date and indicator hand is not adjusted automatically, it must be set manually.

Preliminary position of this watch

The preliminary position of the date is “1” (1st).

The preliminary position of the indicator hand is “low.”

The preliminary position of the hour/minute hands is “12:00 AM”.

3X62_46-01

Adjusting the preliminary position of the date, indicator hand, and hour/minute hands

  1. Pull out the crown to the second click

  2. The seconds hand will move to the 0-second position.

    3X62_46-02 + Preliminary position-1

    Pull out
    the crown to the second click

  3. Continue to press Button B (3 seconds)

  4. The watch enters the mode for setting the preliminary position of the date.

    3X62_46-03 + Preliminary position-2

    Press for 3 seconds

    During movement of the date, the buttons cannot be operated.

    The seconds hand stops at the 18-second position.

    The date moves, and stops when it indicates the preliminary position.

  5. Turn the crown to adjust the date to “1”

  6. Adjust so that the numeral “1” appears in the center of the date window.

    If “1” is displayed, go to operation Sq_4

    3X62_46-04 + Preliminary position-3

    Turn the crown clockwise to advance 1 step.

    Turn the crown counterclockwise to set back 1 step.

    Turn quickly to move continuously.
    Turn again to stop moving.

  7. Press Button B and then release it

  8. The watch enters the mode to adjust the preliminary position of the indicator hand.

    3X62_46-05 + Preliminary position-4

    Press and then release

    The seconds hand stops at the 44-second position.

    The indicator hand turns and stops to indicate the preliminary position.

  9. Turn the crown to adjust the indicator hand to “low”

  10. When the indicator hand points to “low”, go to operation Sq_6

    3X62_46-06 + Preliminary position-5

    Turn the crown clockwise to advance 1 step.

    Turn the crown counterclockwise to set back 1 step.

    Turn quickly to move continuously.
    Turn again to stop moving.

  11. Press Button B and then release it

  12. The watch goes into the preliminary position setting mode of the hour and minute hands.

    3X62_49-01 + Preliminary position-8

    Press and then release

    The seconds hand stops at the 0-second position.

  13. Continue to press Button A (3 seconds)

  14. The hour/minute hands move, and stop at “12:00 AM”.

    3X62_49-02 + Preliminary position-9

    Press for
    3 seconds

  15. Push the crown back in

  16. The watch exits the mode to adjust the preliminary position, and the seconds hand and the hour/minute hands start moving.

    3X62_49-03 + Preliminary position-10

    Push back in

  17. Set the time by receiving GPS signals

  18. When you are in a place where GPS signals can be easily received, adjust the time zone.

    When operations Sq_1 - Sq_8 are complete, be sure to set the time.

    When you are in a place where GPS signals cannot be received

    1. Set the time difference and date manually

    2. Manually set the time

    When the time is set, operation is completed.